Quick answer: Under the 2010 ADA Standards, signs that identify permanent rooms and spaces (restrooms, room numbers, exit stairs) need raised, uppercase, sans-serif characters at least 1/32 inch high, 5/8 to 2 inches tall, with Grade 2 braille. Tactile characters go between 48 inches (baseline of the lowest line) and 60 inches (baseline of the highest line) above the floor, beside the door on the latch side. Directional and informational signs only need the visual rules, such as a non-glare finish and contrast. Confirm requirements for your space with your architect or code official.
Most Rockland County businesses that open to the public, including offices, medical practices, shops, restaurants and schools, need at least a few ADA signs: restrooms, room numbers or names, and exit stairs. The rules come from the 2010 ADA Standards for Accessible Design published by the U.S. Department of Justice. Section 216 says which signs are covered, and section 703 says how they must be made and mounted. This page summarizes both. It isn't legal advice, and your architect, landlord or code official has the final word on your space.
Which Signs Are Covered
- Room and space designations (section 216.2): interior and exterior signs that identify permanent rooms and spaces, like "Restroom," "Office 104," "Conference Room" or "Kitchen." These need raised characters with braille plus the visual rules. The Standards describe these as signs that are not likely to change over time.
- Directional and informational signs (216.3): signs that point to or give information about interior spaces and facilities, such as "Restrooms →," occupant load or rules of conduct. These need to meet the visual character rules in 703.5, but not raised characters or braille.
- Exit doors (216.4.1): doors at exit passageways, exit discharge and exit stairways must be identified by tactile signs.
- Entrances (216.6): where not every entrance is accessible, the accessible entrances must be marked with the International Symbol of Accessibility, and the inaccessible ones need directional signs pointing to the nearest accessible entrance.
What's exempt from section 216: building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos. Temporary signs used for 7 days or less are also exempt. In parking facilities, several of the 216 requirements don't apply.
One more detail: an exterior sign that isn't located at the door to the space it serves doesn't need raised characters under the 216.2 exception.
Raised Characters (Section 703.2)
- Depth: at least 1/32 inch above the background.
- Case: uppercase.
- Style: sans serif. Not italic, oblique, script, highly decorative or other unusual forms.
- Proportions: the width of the uppercase "O" must be 55 to 110 percent of the height of the uppercase "I".
- Height: 5/8 inch minimum and 2 inches maximum, based on the uppercase "I". If separate raised and visual characters carry the same information, raised characters can be as small as 1/2 inch.
- Stroke: the stroke of the uppercase "I" can be no more than 15 percent of the character height.
- Edges: the Standards advise that signs meant to be read by touch shouldn't have sharp or abrasive edges.
Braille (Section 703.3)
Raised characters have to be duplicated in braille. The braille must be contracted (Grade 2) with domed or rounded dots, and it's placed below the corresponding text. Capital-letter indicators are only used before the first word of sentences, proper nouns and names, individual letters, initials and acronyms. Braille dot size and spacing are set by a table in the Standards, which is one reason ADA signs are made with dedicated equipment rather than improvised.
Where the Sign Goes (Section 703.4)
- Height: tactile characters at least 48 inches above the finished floor, measured from the baseline of the lowest tactile character, and no higher than 60 inches, measured from the baseline of the highest tactile character.
- Single door: alongside the door on the latch side.
- Double doors, one active leaf: on the inactive leaf.
- Double doors, two active leaves: to the right of the right-hand door.
- No wall space: on the nearest adjacent wall.
- Clear floor space: an 18-by-18-inch clear floor space, centered on the tactile characters, beyond the arc of the door swing between closed and 45 degrees open. The Standards allow tactile signs on the push side of doors that have closers and no hold-open devices.
Visual Characters, Finish and Contrast (Section 703.5)
Characters and their background must have a non-glare finish, and they must contrast: light characters on a dark background or dark on light. The Standards' advisory notes that shadows from lighting, surface glare and uneven textures also affect legibility for people with low vision. For directional and overhead signs, the minimum visual character height depends on how high the sign is mounted and how far away it's read from, under Table 703.5.5. That's why a hallway directional sign mounted high usually needs bigger letters than a door sign at eye level.
Pictograms and Restroom Symbols
Where pictograms are used to designate permanent interior rooms, such as the familiar restroom symbols, the 2010 Standards require them to meet section 703.6 and to have a text descriptor that meets the raised character and visual rules. In practice, that means a restroom sign typically has the symbol, the word in raised uppercase letters, and Grade 2 braille below.
Planning ADA Signs for a New Space
- Get a door list. Walk the space or use the floor plan and list every permanent room, restroom and exit stair door.
- Note the door hardware. Latch side, double doors and door closers all affect placement.
- Match your look, within the rules. Colors, materials and the shape of the sign plate can match your brand; the raised text has to follow 703.2.
- Check with your architect or code official. New York's building and fire codes and your landlord may add their own requirements, especially for exit and stair signs.
- Plan installation. Mounting height and latch-side placement are easy to get wrong when signs are hung after furniture or wall art.
Opening a new location? Our new business sign checklist puts ADA signs in order with your storefront sign and permits. For lobby and interior branding, see custom signs and CNC & laser cut signs.
What to Send for a Quote
Send your door list with room names or numbers, the quantity of each sign, your preferred colors, whether you need pictograms, and any requirements from your architect or landlord. A photo of a typical door and wall helps confirm placement. Call (845) 579-3685 or use the form below.
Common Questions
What signs have to be ADA compliant?
Under section 216 of the 2010 ADA Standards, signs that identify permanent rooms and spaces, like restrooms, room numbers and exit stairways, need tactile characters and braille. Directional and informational signs must meet the visual character rules. Some signs, like company names and logos, building addresses, menus and temporary signs used for 7 days or less, are exempt from section 216.
How high do ADA signs go on the wall?
Section 703.4.1 puts tactile characters at least 48 inches above the floor, measured to the baseline of the lowest tactile character, and no more than 60 inches, measured to the baseline of the highest tactile character.
Which side of the door does an ADA sign go on?
The latch side. At double doors with one active leaf, it goes on the inactive leaf; with two active leaves, to the right of the right-hand door. If there's no wall space, use the nearest adjacent wall.
Do ADA signs need braille?
Signs with raised characters must be duplicated in contracted (Grade 2) braille under section 703.2 and 703.3.
Can an ADA sign use my brand font?
Not for the raised characters. They must be uppercase and sans serif, and can't be italic, script or highly decorative. Your logo and company name are exempt from section 216, so they can appear in your brand style elsewhere.
Sources
Related
Custom signs · Channel letters · Sign costs · Sign size & permit guide · Window graphics · Service areas
Get a Quote
Call (845) 579-3685 or send details below.